LK Automation Limited LK Automation Limited
Brand Sort: MITSUBISHI
Home >> Price
MITSUBISHI AY15EU Price
  • Brand: MITSUBISHI
  • Country: JAPAN
  • Name: Relay output module
  • Model: AY15EU
  • Price: 0
  • >
MITSUBISHI AY15EU
Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC12/24.
Input current: 3/7mA.
Output type: transistor drain type.
Output points: 32 points.
Common public end points: 32.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control AY15EU
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.The length of the line: 2M.
Relay type.
IP level: IP20.
Bending life: high bending life.
Encoder with cable (amplifier side); for HF-KP/HF-MP series. 15 inches.
Surface treatment: anti reflective film.
Protective film color: No.
USB protection cover parts: there is an opening.
Set number: 5.
Applicable model: GT27. Output points: 24 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public side.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system.
At the same time, the use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information.
AY15EU Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=AY15EU&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Relay output module
AY11
MITSUBISHI Relay output module AY11
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY13
MITSUBISHI Relay output module AY13
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY13C
MITSUBISHI Relay output module AY13C
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11AEU
MITSUBISHI Relay output module AY11AEU
Output points: 16 points. Voltage: DC24V