Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V.
OFF leakage current: 0.1mA.
Output response time: 12ms.
Output type: transistor output.
8 point /1 a public side.
With the surge absorber.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control
A9GT-QC200BS
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal. Points: 32 points
.
Rated voltage: DC24V.
Connection type: connector
.
Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to those who require only the ON/OFF control function of the field components, such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data.
Remote components: refers to those that require processing of the register data of the field components, such as analog I/O and counters, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of component is to allow the main station or other stations to access the action, to collect data and control the local PLC station,
GOTS and programmer interface unit are of this type.
A9GT-QC200BS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A9GT-QC200BS&select=5