Servo amplifier side connector.Extension cable.
Length: 1000mm. Protective film for 5.7 inch screen.
Transparent (frame: white), 5.
Applicable model: GT14. Control axis: up to 16 axes.
Interpolation function: linear interpolation (maximum 4 axis), arc interpolation (2 axis), spiral interpolation (3 axis).
PLC capacity: 60K step.
Can control the maximum 16 axis servo amplifier.
With the position control, speed control, torque control, advanced synchronous control and other rich control methods
A62DA-S1
The incremental synchronous encoder I/F and the symbol detection signal I/F are integrated in the 1 modules.
Capacity expansion can be expanded to PLC capacity 60K step (using Q170MSCPU-S1), the 7 layer of the substrate.
Combined with the servo amplifier to achieve safe torque off (STO).
Connect directly to the visual system produced by Ethernet through the COGNEX connection.
Connection SSCNET III /H main module LJ72MS15 can use the MELSEC-L series of input.
Output module, analog input and output module, high speed counter module.RS-232 1 channels.
With DC input 2 points.
Transistor output 2.
Number of stations: 1 stops.
Station type: intelligent equipment station.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
A62DA-S1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A62DA-S1&select=5