Compact flash memory card.
Capacity: 2GB bytes. Function: CPU module (internal service power supply).
Input and output points: 32 points.
Power supply capacity (DC5V power): 900mA.
Power supply capacity (DC24V service power supply): 400mA.
Input / output mode: DC input (drain / source) / transistor (drain).
Input points: 16 points.
Output points: 16 points.
The new expansion module is more convenient!
Pioneer products with advanced built-in functions and rich extensibility
A1NCPUR21
FX5U built-in analog, communication, high speed input and output,
By extending the board and adapter can be easily extended system.
In addition, through the high speed system bus,
Can maximize the role of the built-in intelligent functions of the expansion device.
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
A1NCPUR21 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A1NCPUR21&select=5