Max input / output points: 30 points.
Power supply voltage: DC24V.
Input points: 16 points.
Output points: 14 points.
Output type: Transistor (source).
Power consumption (W): 21.
Weight (kg):0.45.
Size (WxHxD) mm:100x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control
HC-UF502
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. 10BASE-T/100BASE-TX.
Ethernet interface module capable of selecting the most suitable system and object device.
Support 100BASE-TX, can speed up the transmission speed. (QJ71E71-100)
Data communication can be performed between programmable controller CPU using special instructions.
Can use the HTTP protocol, through the Web browser on the PC access to the soft element of the programmable controller.
PC (Web) on the use of the communication program library and sample screen can be obtained by download services.
Can connect a number of programming tools to improve the efficiency of debugging.
Make use of e-mail function, through the mail server to send e-mail (ASCII format) and attachments (binary, ASCII and CSV format).
The KeepAlive function can be used to perform the existence of the object equipment inspection, and keep the connection in the open state.
This can be used to ensure connectivity and to quickly find errors.