MITSUBISHI GT2508-VTWA-GF
DC input points: 32 points.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public side.
Output form: relay output.
36 point terminal table * 2.
Number of stations: 8 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program GT2508-VTWA-GF
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. RS-232 1 channels.
With DC input 2 points.
Transistor output 2.
Number of stations: 1 stops.
Station type: intelligent equipment station.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
GT2508-VTWA-GF Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=GT2508-VTWA-GF&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
8.4 Inch Touch Screen
GT2508-VTWD-GF
MITSUBISHI 8.4 Inch Touch Screen GT2508-VTWD-GF
Function: high performance and low price
MITSUBISHI
8.4 Inch Touch Screen
GT2508-VTBD
MITSUBISHI 8.4 Inch Touch Screen GT2508-VTBD
Function: high performance and low price
MITSUBISHI
8.4 Inch Touch Screen
GT2508-VTWA-GF
MITSUBISHI 8.4 Inch Touch Screen GT2508-VTWA-GF
Function: high performance and low price
MITSUBISHI
8.4 Inch Touch Screen
GT2508-VTBA
MITSUBISHI 8.4 Inch Touch Screen GT2508-VTBA
Function: high performance and low price