LK Automation Limited LK Automation Limited
Brand Sort: MITSUBISHI
Home >> Price
MITSUBISHI FR-F840-00023-2-60 Price
MITSUBISHI FR-F840-00023-2-60
DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control FR-F840-00023-2-60
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized. Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0.3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program.
No need to use ladder diagram conversion program, can reduce the programming time.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components.
Can be selected from low pass filter, high pass filter, medium pass filter.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened.
FR-F840-00023-2-60 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FR-F840-00023-2-60&select=5


...more relevant model market price >>>>
Related products