Motor series: low inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 5.0kw.
Rated speed: 3000rpm.
With a brake band.
Shaft end: straight shaft.
Performance comparison of servo motor and stepping motor.
Stepper motor as an open-loop control system, and modern digital control technology has the essential link.
In the current domestic digital control system, stepping motor is widely used
A7GT-MCA256K-LD
With the emergence of digital AC servo system, AC servo motor is more and more used in digital control system.
In order to adapt to the development trend of digital control, most of the motion control system adopts stepping motor or full digital AC servo motor as executive motor.
Although they are similar in control mode (pulse train and directional signal), there are great differences in performance and application.
The use performance of the two are compared. Master station.
Support DB A20 AnyWire system.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. SI-200/250 fiber optic cable.
Double loop.
MELSECNET (II) (remote I/O station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
A7GT-MCA256K-LD Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A7GT-MCA256K-LD&select=5