LK Automation Limited LK Automation Limited
Information sort MITSUBISHI
Home >> Supply
MITSUBISHI FR-F842-12120-2-60 Rectifying partial off type frequency converter FR-F842-12120-2-60

Max input / output points: 14 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 6 points.
Output type: Transistor (source).
Power consumption (W): 6.5.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FR-F842-12120-2-60.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FR-F842-12120-2-60.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-F842-12120-2-60.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. Power: 75kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor MITSUBISHI FR-F842-12120-2-60.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available.
Please select according to the required braking torque.
MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V MITSUBISHI FR-F842-12120-2-60.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON MITSUBISHI FR-F842-12120-2-60.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. Convert connectors to e-CON.RS-232C communication adapter.
(need FX1N-CNV-BD).
(FX1S and FX1N host general). Power: 1.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay aattention to the allowable brake use rate FR-F842-12120-2-60.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor.
Related supply information